310 research outputs found

    Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

    Get PDF
    PURPOSE: The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. METHODS: A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. RESULTS: There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4-6.4, TC-STSF: mean = 3.2 years, 95% CI = 3-3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14-30) than TC-STSF (14 min, IQR: 8-25; p = 0.04). CONCLUSION: Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA

    The HETDEX Pilot Survey III: The Low Metallicities of High-Redshift Lyman Alpha Galaxies

    Full text link
    We present Keck/NIRSPEC spectroscopic observations of three Lyman alpha emitting galaxies (LAEs) at z ~ 2.3 discovered with the HETDEX pilot survey. We detect Halpha, [OIII], and Hbeta emission from two galaxies at z = 2.29 and 2.49, designated HPS194 and HPS256, respectively, representing the first detection of multiple rest-frame optical emission lines in galaxies at high-redshift selected on the basis of their Lyman alpha emission. The redshifts of the Lyman alpha emission from these galaxies are offset redward of the systemic redshifts by Delta_v = 162 +/- 37 (photometric) +/- 42 (systematic) km/s for HPS194, and Delta_v = 36 +/- 35 +/- 18 km/s for HPS256. An interpretation for HPS194 is that a large-scale outflow may be occurring in its interstellar medium. The emission line ratios imply that neither LAE hosts an active galactic nucleus. Using the upper limits on the [NII] emission we place meaningful constraints on the gas-phase metallicities in these two LAEs of Z < 0.17 and < 0.28 Zsol (1 sigma). Measuring the stellar masses of these objects via spectral energy distribution (SED) fitting (~ 10^10 and 6 x 10^8 Msol, respectively), we study the nature of LAEs in a mass-metallicity plane. At least one of these two LAEs appears to be more metal poor than continuum-selected star-forming galaxies at the same redshift and stellar mass, implying that objects exhibiting Lyman alpha emission may be systematically less chemically enriched than the general galaxy population. We use the SEDs of these two galaxies to show that neglecting the emission lines when fitting stellar population models to the observed photometry can result in overestimates of the population age by orders of magnitude, and the stellar mass by a factor of ~ 2. This effect is particularly important at z > 7, where similarly strong emission lines may masquerade in the photometry as a 4000 A break (abridged).Comment: Replaced with the accepted (to ApJ) versio

    Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    Get PDF
    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 +/- 8 years, 25 men, mean left ventricular ejection fraction 31 +/- 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Results Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Conclusion Catheter-based substrate modification using voltage mapping results in a long-lasting reduction of cardioverter defibrillator therapy in patients with multiple and/or hemodynamically not tolerated infarct-related ventricular tachyarrhythmia

    Oral anticoagulant re-initiation following intracerebral hemorrhage in non-valvular atrial fibrillation: Global survey of the practices of neurologists, neurosurgeons and thrombosis experts

    Get PDF
    <div><p>Background</p><p>While oral anticoagulants (OACs) are highly effective for ischemic stroke prevention in atrial fibrillation, intracerebral hemorrhage (ICH) remains the most feared complication of OAC. Clinical controversy remains regarding OAC resumption and its timing for ICH survivors with atrial fibrillation because the balance between risks and benefits has not been investigated in randomized trials.</p><p>Aims/Hypothesis</p><p>To survey the practice of stroke neurologists, thrombosis experts and neurosurgeons on OAC re-initiation following OAC-associated ICH.</p><p>Methods</p><p>An online survey was distributed to members of the International Society for Thrombosis and Haemostasis, Canadian Stroke Consortium, NAVIGATE-ESUS trial investigators (Clinicatrials.gov identifier NCT02313909) and American Association of Neurological Surgeons. Demographic factors and 11 clinical scenarios were included.</p><p>Results</p><p>Two hundred twenty-eight participants from 38 countries completed the survey. Majority of participants were affiliated with academic centers, and >20% managed more than 15 OAC-associated ICH patients/year. Proportion of respondents suggesting OAC anticoagulant resumption varied from 30% (for cerebral amyloid angiopathy) to 98% (for traumatic ICH). Within this group, there was wide distribution in response for timing of resumption: 21.4% preferred to re-start OACs after 1–3 weeks of incident ICH, while 25.3% opted to start after 1–3 months. Neurosurgery respondents preferred earlier OAC resumption compared to stroke neurologists or thrombosis experts in 5 scenarios (p<0.05 by Kendall’s tau).</p><p>Conclusions</p><p>Wide variations in current practice exist among management of OAC-associated ICH, with decisions influenced by patient- and provider-related factors. As these variations likely reflect the lack of high quality evidence, randomized trials are direly needed in this population.</p></div

    Alpha-2-Macroglobulin Is Acutely Sensitive to Freezing and Lyophilization: Implications for Structural and Functional Studies.

    Get PDF
    Alpha-2-macroglobulin is an abundant secreted protein that is of particular interest because of its diverse ligand binding profile and multifunctional nature, which includes roles as a protease inhibitor and as a molecular chaperone. The activities of alpha-2-macroglobulin are typically dependent on whether its conformation is native or transformed (i.e. adopts a more compact conformation after interactions with proteases or small nucleophiles), and are also influenced by dissociation of the native alpha-2-macroglobulin tetramer into stable dimers. Alpha-2-macroglobulin is predominately present as the native tetramer in vivo; once purified from human blood plasma, however, alpha-2-macroglobulin can undergo a number of conformational changes during storage, including transformation, aggregation or dissociation. We demonstrate that, particularly in the presence of sodium chloride or amine containing compounds, freezing and/or lyophilization of alpha-2-macroglobulin induces conformational changes with functional consequences. These conformational changes in alpha-2-macroglobulin are not always detected by standard native polyacrylamide gel electrophoresis, but can be measured using bisANS fluorescence assays. Increased surface hydrophobicity of alpha-2-macroglobulin, as assessed by bisANS fluorescence measurements, is accompanied by (i) reduced trypsin binding activity, (ii) increased chaperone activity, and (iii) increased binding to the surfaces of SH-SY5Y neurons, in part, via lipoprotein receptors. We show that sucrose (but not glycine) effectively protects native alpha-2-macroglobulin from denaturation during freezing and/or lyophilization, thereby providing a reproducible method for the handling and long-term storage of this protein.Early Career Fellowship from the National Health and Medical Research Council GNT1012521(A.R.W.); Wellcome Trust Programme Grant (J.R.K., C.M.D.) 094425/Z/10/Z; Samsung GRO Grant (M.R.W.)This is the final version of the article. It first appeared from PLoS via http://dx.doi.org/10.1371/journal.pone.013003

    Functional Modifications of Acid-Sensing Ion Channels by Ligand-Gated Chloride Channels

    Get PDF
    Together, acid-sensing ion channels (ASICs) and epithelial sodium channels (ENaC) constitute the majority of voltage-independent sodium channels in mammals. ENaC is regulated by a chloride channel, the cystic fibrosis transmembrane conductance regulator (CFTR). Here we show that ASICs were reversibly inhibited by activation of GABAA receptors in murine hippocampal neurons. This inhibition of ASICs required opening of the chloride channels but occurred with both outward and inward GABAA receptor-mediated currents. Moreover, activation of the GABAA receptors modified the pharmacological features and kinetic properties of the ASIC currents, including the time course of activation, desensitization and deactivation. Modification of ASICs by open GABAA receptors was also observed in both nucleated patches and outside-out patches excised from hippocampal neurons. Interestingly, ASICs and GABAA receptors interacted to regulate synaptic plasticity in CA1 hippocampal slices. The activation of glycine receptors, which are similar to GABAA receptors, also modified ASICs in spinal neurons. We conclude that GABAA receptors and glycine receptors modify ASICs in neurons through mechanisms that require the opening of chloride channels
    corecore